solvent compatibility 0.22 um syringe filter for petrochemicals

Home » News » Membane filter » solvent compatibility 0.22 um syringe filter for petrochemicals
<h3>Millex-GS Syringe Filter Unit, 0.22 µm, mixed cellulose </h3>

Millex-GS Syringe Filter Unit, 0.22 µm, mixed cellulose

Millex-GS Syringe Filter Unit, 0.22 µm, mixed cellulose esters, 33 mm, ethylene oxide sterilized A 33 mm diameter sterile syringe filter with a 0.22 µm pore size Mixed Cellulose Esters membrane. Comes in a pack of 250. - Find MSDS or SDS, a COA, data sheets and more information.

<h3>Syringe Filters | Thermo Fisher Scientific - US</h3>

Syringe Filters | Thermo Fisher Scientific - US

Use these all-plastic disposable syringes with your Titan3, Target2, and Choice Basic syringe filters. Comprising a polypropylene barrel and polyethylene plunger, these syringes eliminate problems with rubber or synthetic plunger gaskets and requires no silicone or oil lubricant in the barrel. Choose from in 1, 3, 5, 10, 20, 30, and 50 mL sizes.

<h3>Syringe Filter Chemical Compatibility - scientificfilters.com</h3>

Syringe Filter Chemical Compatibility - scientificfilters.com

filtered using syringe filters. Syringe filters can be sterilized by autoclave at 125°C for 15 minutes. The inlet connection is an enhanced female Luer-Lok fitting designed for extra security when attached to a Luer-Lok syringe. The outlet fitting is a standard size male Luer-slip Ion Chromatography (IC) Syringe Filters PES Syringe Filters are

<h3>Syringe Filters - Pall Corporation</h3>

Syringe Filters - Pall Corporation

Syringe filters with different pore size ratings are suitable for different applications. For example, syringe filters containing 0.45 μm are typically used for HPLC sample preparation and 0.2 μm is used for UHPLC. In life science applications 0.1 and 0.2 µm pore sizes provide sterilization of buffers, culture media, and additives.

<h3>Syringe Filters Solvent Compatibility Chart - Restek</h3>

Syringe Filters Solvent Compatibility Chart - Restek

Luer lock inlet provides strong, leak-tight syringe connection to withstand filtration pressure. Rugged polypropylene construction— autoclavable to 121 °C for 15 minutes (75 psi). Labeled (13, 25, and 30 mm, only) and color coded for easy identification. Convenient dispenser box.

<h3>Syringe Filter Solvent Compatibility [Charts] - Growing Labs</h3>

Syringe Filter Solvent Compatibility [Charts] - Growing Labs

Intro. There are so many solvents and syringe filter/membrane materials that it can be tough to remember which combinations are safe and which are corrosive. These tables show five common syringe filter materials -- Cellulose Acetate (CA), Nylon, PES, PTFE, and PVDF -- and their compatibilities with 75 common solvents.

<h3>Durapore® 0.1 µm and 0.22 µm Cartridge Filters - Durapore </h3>

Durapore® 0.1 µm and 0.22 µm Cartridge Filters - Durapore

Description A trusted name in the industry for over 25 years, Durapore® sterilizing-grade 0.1 µm and 0.22 µm hydrophilic polyvinylidene fluoride (PVDF) membranes are low protein binding* and provide sterility assurance, high flow rates and throughputs.

<h3>Orange PTFE (Hydrophobic) Syringe Filters, 0.22 µm, 17 mm </h3>

Orange PTFE (Hydrophobic) Syringe Filters, 0.22 µm, 17 mm

02542884. 243.00 USD. Login to view your price. Request More Information. Add To Cart. Overview. Hydrophobic PTFE syringe filters have broad chemical compatibility and high pH resistance. These are versatile filters for use with aggressive organic solvent-based solutions and are especially ideal for HPLC sample preparation.

<h3>Membrane Filter Chemical Compatibility Chart</h3>

Membrane Filter Chemical Compatibility Chart

1) Syringe filter housings are manufactured from solvent-resistant, low-extractable polypropylene resins specifically selected for wide compatibility with common HPLC sample matrices. 2) Solutions at temperatures up to 100°C can be filtered using syringe filters. 3) Syringe filters can be sterilized by autoclave at 125°C for 15 minutes.

<h3>Millex® Syringe Filters - Sigma-Aldrich</h3>

Millex® Syringe Filters - Sigma-Aldrich

Medical Millex-GP Syringe Filter Unit, 0.22 µm, polyethersulfone, 33 mm, sterilized by gamma irradiation, A 33 mm diameter sterile syringe filter with a 0.22 µm pore size hydrophilic Polyethersulfone (PES) membrane. Comes in a pack of 50.

<h3>Corning Filtration Guide</h3>

Corning Filtration Guide

biological fluids. Refer to Table 3 for more chemical compatibility information. Polypropylene (PP) is used in the Spin-X® centrifuge filters and some of the syringe and disc filter housings. This plastic polymer has very good resistance to many solvents, refer to Table 3 for more chemical compatibility information.

<h3>Syringe Filters - Sigma-Aldrich</h3>

Syringe Filters - Sigma-Aldrich

SLGPM33RS. Medical Millex-GP Syringe Filter Unit, 0.22 µm, polyethersulfone, 33 mm, sterilized by gamma irradiation, A 33 mm diameter sterile syringe filter with a 0.22 µm pore size hydrophilic Polyethersulfone (PES) membrane. Comes in a pack of 50. 0.22 μm pore size.

<h3>Premium Syringe Filters - Chemical Compatibility Chart</h3>

Premium Syringe Filters - Chemical Compatibility Chart

Premium Syringe Filters - Chemical Compatibility Chart Premium Syringe Filters - Chemical Compatibility Chart •• *CA and GF membranes in MBS housing for 28 mm size Contact time:24 hours at 20 °C Chemical compatibilities can be influenced by various factors.

<h3>Red PTFE (Hydrophilic) Syringe Filters, 0.22 µm, 25 mm (100 </h3>

Red PTFE (Hydrophilic) Syringe Filters, 0.22 µm, 25 mm (100

The PerkinElmer Red PTFE (Hydrophilic) Syringe Filters, 0.22 µm, 25 mm (100/pack) have broad chemical compatibility and high pH resistance and are optically clear when wet with water.

ZHEJIANG AIJIREN,INC. is one of the China leading HPLC autosampler vials manufacturers and suppliers, welcome to wholesale HPLC autosampler vials from us.
              Stay Connected
               
Inquiry
Copyright 2021 Zhejiang Aijiren Technology, Inc. All Rights Reserved.